Oct 5, 2019 Version 1.1.0.1 Mic Calibration: Progress bar and Abort button Improved error messages Calibration Process reduced to 10 seconds Warning message if user runs analyzer without first performing mic calibration Cal Results appended to history file(see attached for example). Filename is: C:\Documents\ABC\VivAlarm\MicCalibrationHistory.txt Defaults: Black background and green main trace on plots Mic on left, accel on right with appropriate scaling and calibration Data Logging defaults are appropriate for each channel Misc: Total power utility window caption shows freq span for each channel Increased frequency resolution to gain lower frequency limit on accel channel Acceleration Warning and Danger overlays are installed Changed address on startup screen from 1225 Tendick to 1351 Lincoln Ave Nov 1, 2019 Version 1.1.0.2 Added Peak Hold values column to Utility measurement windows Added "Start analyzer when program opens" option to Device dialog Peak Hold total power now shown on veritical power bar to right of plot Changed size and position of Run and Stop buttons to make it easire on small computer screens Fixed problem with \Temp folder in dialog box Dec 12, 2019 Version 1.1.0.2A Save config file when processing settings dialog closes Feb 19, 2020 Version 1.1.0.3 Added Species button to load configuration files Improved data logging logic to show Logging Start and Stop times when no events occur Mar 11, 2020 Version 1.1.0.4 Added Environmental sensors (Temp, Humidity, Light): - Added to Data Logging (left channel) - Utility Window with current values Jun 9, 2020 Version 1.2.0.0 ---------------------------------- Oct 19 2020 - Sensory Sentinel v2.0.0.4 - Changed SystemID/Name/Company location from INI file to Registry Oct 22 2020 - Sensory Sentinel v2.0.0.5 - Implemented Email Alerts - Improved logic for midnight rollover of data log - Updated Help File Dec 3 2020 - Sensory Sentinel v2.0.0.6 - Fixed logic error with Cc addresses - Changed alert duration from minutes to seconds - Added alert hold off time parameter - Implemented time controls for duration and hold off times - Changed email reply address to - Expanded the email title to include the alert type Dec 30 2020 - Sensory Sentinel v2.0.0.7 - Label changes to email alert dialog box - New and revised species and overlay files - Logic change to fix mic calibration crash Feb 10 2020 - Sensory Sentinel v2.0.0.8 - Activity Screens and data logic Oct 1 2021 - Sensory Sentinel v3.0.0.2 beta Prevent crash if reading corrupted .csv file Prevent copying to the network folder at the same time as writing the log file (the likely cause of frozen data issue) Activity screen: - used same warm red color for emergency contact background and PPE and special notes text - moved data log plot button to top right by current value circles Data Plot screen - moved the labels below the activity icons up slightly - use black background and colored text for activity bar labels Oct 15 2021 - Sensory Sentinel v3.0.0.3 beta Fixed issue with calendar control where multiple message boxes appeared Fixed issue with PPE Special notes not allowing blank lines between row of text Added option to disable Email alerts during activity periods Added timeout option to revert back to Activity Screen from data log screen Added listbox of most recent labels for "other" activity type so user can quickly select Made generic PPE label and Other activity labels all upper case text Updated Help file contents Prevent multiple copies from running on same PC Nov 10 2021 - Sensory Sentinel v3.0.0.4 Fixed issue causing activity data to be shown in successive days when system is stopped for over 24 hours Reduced CPU load to help prevent PC shutdown due to overheating resulting in frozen/duplicate data Nov 17 2021 - Sensory Sentinel v3.0.0.5 Station Viewer - fixed crash with large file sets Dec 2 2021 - Sensory Sentinel v3.0.0.5A Special notes stored in time history files Added "Special Notes" button on sidebar to read and display them Added Auto Scroll Time Axis feature Updated to VS2017 compiler Added support for Virtins DAQ hardware Jan 20 2022 - Sensory Sentinel v3.0.0.6 Automatically creates /Temp folder if missing Changes to support DAQ-200 version 2.0 Fix for right click on touch screens Jul 5 2022 - Sensory Sentinel v3.1.0.0 Additional sensor values added to alert email body Added time stamp below each plot Implemented Staion Viewer composite email alert functionality Aug 25 2022 - Sensory Sentinel v3.1.0.2 Emails now sent using Microsoft Azure (developer mode) Sep 15 2022 - Sensory Sentinel v3.1.0.3 Improved Alert Email error handling Azure Emails now using TS registered domain (release mode) Oct 19 2022 - Sensory Sentinel v3.1.0.4 Fixed build issue with Azure email component Nov 4 2022 - Sensory Sentinel v3.1.0.4A Fixed issue with replicated data when the PC resumes after beings suspended but on a different date MicCalibrationRawData.wav is written after mic calibration for troubleshooting Informational message appears for 3 seconds if user clicks on calendar to a date when no file exists Nov 10 2022 - Sensory Sentinel v3.1.0.5 Added AVG parameter to metrics Monthly Report utility (Station Viewer) Jan 4 2023 - Sensory Sentinel v3.1.0.6 (station viewer only) Improved Email alert logic Fixed Temperature alerts when Celcius units selected Jan 18 2023 - Sensory Sentinel v3.1.0.7 Station Monitor - Updated threshold levels for all data log plots - Updated thresholds in species files - Disable Alerts during activities now only applies to noise and vibration. Temp/RH/Lux alerts will still be sent during activities. The label was changed on the check box to reflect this. Station Viewer - Added Temp path parameter to Set File Storage Locations dialog box for easier tech support of file issues - Changed logic for sending email alert error if data log file is not updating. Error occurs after the file is not updated for 15 minutes. The error is not sent again for 4 hours. Mar 13 2023 - Sensory Sentinel v3.1.0.8 Station Viewer - added "Event" report Apr 7 2023 - Station Viewer v3.1.0.8A Added 1/1 and 1/3 Octave to mic channel Fixed time stamp issue on advanced data logging July 26 2023 - Sensory Sentinel v3.1.0.9 Support for Tick@lab for internal testing at Turner Sept 5 2023 - Sensory Sentinel v3.2.0.0 Added support for Hydrophone calibration and units Added renewal notification banner and associated logic Installer no longer prompts for StationID, name and company (now done by the app only if new installation). Oct 13 2023 - Sensory Sentinel v3.2.0.1 Removed Tick@lab menu Application maximizes when opened Added Zebrafish species file Nov 14 2023 - Sensory Sentinel v3.2.0.1A Station Viewer - Added ability to send Composite Email Alerts based on noise thresholds Jan 2 2024 - Station Viewer v3.2.0.2 Added Tick@lab menu with account setup Feb 22 2024 - Sensory Sentinel v3.2.0.3 Added Hold Off time to Composite Alerts Added Config file menu, file path and command line logic Feb 29 2024 - Station Viewer v3.2.0.3 Changed endpoint web location for Tick@lab uploads Mar 6 2024 - Sensory Sentinel v3.2.0.3A Added Velocity measurements: Data Log Plot option (Acceleration or Velocity) Both Acceleration and Velocity data are stored in history files Current Vibration value circle shows Accel or Velocity based on plot option Station Viewer - added StationID and Name to main application caption bar Oct 23 2024 - Sensory Sentinel v4.0.0.0 Changed Velocity to use the level of the peak frequency (not RMS total) to allow comparison to what is used in the building construction industry. Station Viewer - added support for velocity Station Viewer - application caption bar now shows station id for helping with report preparation Jan 2 2025 - Sensory Sentinel v4.0.0.1 Jan 2 2025 - Station Viewer v4.0.0.1 Added fields for mic and accel serial numbers on the calibration dialog box Added support for light spectrum sensor Use the menu to open the plot Improved logic for the Tick@lab "Test Connection" function Feb 17 2025 - Sensory Sentinel v4.5.0.0 Fixed issue with Tick@lab auto upload stopping after closing and reopening the program Mar 26 2025 - Sensory Sentinel v4.5.0.1 Added logic change to write settings to .cfg file whenever Ok is clicked on a dialog box instead of when the program exits. This will keep settings current when the system reboots for a Windows update. Mar 27 2025 - Sensory Sentinel v4.5.0.2 Optimized logic of reading environmental sensor values Apr 9 2025 - Sensory Sentinel v4.5.0.3