Spectrum Display Options
The spectrum display options dialog box can be activated by selecting the Options | Plot Options menu and clicking the Spectrum tab or by clicking on the options dialog icon button in the view toolbar.
Plot Type: You can change between line and bar graphs by clicking on the toolbar controls or from the spectrum display options dialog box. The line or stepped bar graph option is recommended when using large FFT sizes . The bar graph option is recommended when Octave scaling is selected or when zoomed in with narrowband scaling.
Plot Top/Range: The Plot Top and Range values determine the amplitude axis scale values. Plot Top is the value at the upper edge of the plot. The lower edge of the plot is always equal to the Top value minus the Range value. When linear scaling is selected for the amplitude axis, the Plot Range value is set to zero and cannot be changed.
Peak Hold: Control the behavior of the Peak Hold trace showing the highest amplitude values for each frequency bin. For information on the Peak Hold feature see the Peak Hold topic.
Pull Cursor to Trace: If this option is enabled, the measurement cursor will automatically "pull" to the spectrum trace along the amplitude axis.
Pull to Peak Hold if enabled: this allows you to have the cursor pull to the peak hold trace instead of the normal trace. If peak hold is off the cursor will pull to the normal trace.
Thick Traces and Markers: Increases the line thickness of these items for better visibility on some displays
Show Toolbar: Show or hide the plot toolbar.
Show Overlay Controls: Show or hide the overlay controls on the right side of the Spectrum Plot. A small + or - button below the overlay controls also controls this feature.
Colors: The color of each plot feature can be changed. Only solid colors can be selected. The "Default" button will restore the initial colors settings.
Marker Options: Setup the markers. The marker settings can also be accessed by clicking the "Mrk" button on the spectrum plot toolbar.
Grid Lines: Show or hide the grid lines.
Frequency Span: Although the displayed frequency span can easily be selected using the zoom buttons on the toolbar, you can also manually enter the span yourself. The span is limited to the total available span. The actual span displayed may vary slightly from the requested values because the values are adjusted to the nearest bin.
Display Update Interval: Controls how often the display is updated. This is useful on some laptop computers with slow display refresh rates to reduce flicker.
Show Total Power Meter: the total power meter is located along the right side of the spectrum plot and shows the "Total" power of the spectral data. This value is equal to the Total Power utility. A different weighting curve can be applied to this value (this is set in the Scaling dialog box). A small + or - button below the meter also controls this feature.
Show Zoomed Power Level: If enabled, the RMS Power level will be computed and displayed above the top left corner of the plot. This power level is computed for the currently displayed span and will change as you zoom in and out. Use this feature to compute the power within any segment of the spectrum. The weighting used for this calculation is the same as the spectrum weighting parameter in the scaling dialog box.